AC Electric Rotary Isolation Disconnect Switch
  • AC Electric Rotary Isolation Disconnect SwitchAC Electric Rotary Isolation Disconnect Switch
  • AC Electric Rotary Isolation Disconnect SwitchAC Electric Rotary Isolation Disconnect Switch
  • AC Electric Rotary Isolation Disconnect SwitchAC Electric Rotary Isolation Disconnect Switch
  • AC Electric Rotary Isolation Disconnect SwitchAC Electric Rotary Isolation Disconnect Switch
  • AC Electric Rotary Isolation Disconnect SwitchAC Electric Rotary Isolation Disconnect Switch
  • AC Electric Rotary Isolation Disconnect SwitchAC Electric Rotary Isolation Disconnect Switch

AC Electric Rotary Isolation Disconnect Switch

Ang ADELS® ay isang dalubhasa sa mataas na kalidad na tagagawa at supplier ng AC Electric Rotary Isolation Disconnect Switch sa China. Ang AC Electric Rotary Isolation Disconnect Switch ay idinisenyo at ginawa, ayon sa GB/14048.3 at IEC60947-3, FM30 series load isolation switch ay ginagamit para sa AC 50Hz, rated operational voltage hanggang 440V, rated current hanggang 100A sa mga electrical circuit, para sa pagpapasok ng hangin kagamitan, air condition at water pump sa master switch ng system, maaari ding direktang kontrolin ang maliit na kapasidad na motor. Mag-book ng konsultasyon ngayon at tingnan kung paano tumutugma ang aming mga switch sa iyong mga pangangailangan sa market.

Modelo:FM30

Magpadala ng Inquiry    PDF Download

Paglalarawan ng Produkto

ADELS

AC Electric Rotary Isolation Disconnect Switch


â¢Ambient temperature Huwag lumampas sa 40 °C , at ang average na temperatura, Measuerd over aperiod na 24h, ay hindi hihigit sa 35°C ;
â¢Ang temperatura ng kapaligiran ay hindi dapat mas mababa sa -250°C;
â¢Hindi dapat i-install nang higit sa 2000m sa ibabaw ng dagat;
â¢Ang pinakamataas na temperatura na 40°C, relatibong halumigmig ng hangin na hindi hihigit sa 50%. Sa mas mababang temperatura, Ang isang mas mataas na halumigmig ay pinapayagan, Tulad ng sa 20°C, hanggang sa 90% halumigmig pinapayagan Ito ay dapat magpatibay ng espesyal na paggamot laban sa condensation na tubig.



Pagpapakilala ng AC Electric Rotary Isolation Disconnect Switch


â¦Ang FM30 series load isolation switch ay ginagamit para sa AC 50Hz, rated operational voltage hanggang 440V, rated current hanggang 100A sa mga electrical circuit, para sa ventilating equipment, air condition at water pump sa master switch ng system, maaari ding direkta kontrolin ang maliit na kapasidad na motor.
â¦Sumusunod ang mga rotary switch sa: GB/14048.3 at IEC60947-3.
.Mga detalye ng switch ng serye ng FM30, 20A, 25A, 32A, 40A, 63A at 80A, 100A kasalukuyang rating.
â¦Ang switch ng FM30 series ay may maliit na sukat, compact na istraktura, seleksyon ng katangi-tangi, mahusay na insulated, na may function ng daliri, ligtas at maaasahan, maaari kang magdagdag ng iba sa 3-pole standard block contact nang hindi kinakailangang lansagin ang switch.
â¦Mga distansya ng pagkakabukod ng switch ng FM30 series na mas malaki kaysa sa isa pang switch, idiskonekta ang bilis, na naaangkop sa DC switching.


Normal na kondisyon sa pagtatrabaho


â¦Temperatura sa paligid Huwag lumampas sa 40 °C , at ang average na temperatura, Sukatin sa loob ng 24h, hindi hihigit sa 35°C ;
â¦Ang ambient temperature ay hindi dapat mas mababa sa -250°C;
â¦Hindi dapat i-install nang higit sa 2000m sa ibabaw ng dagat;
â¦Ang pinakamataas na temperatura na 40°C, relatibong halumigmig ng hangin na hindi hihigit sa 50%. Sa mas mababang temperatura, Ang isang mas mataas na halumigmig ay pinapayagan, Tulad ng sa 20°C, hanggang sa 90% halumigmig pinapayagan Ito ay dapat magpatibay ng espesyal na paggamot laban sa condensation na tubig.


Mga kondisyon sa pag-install


Kailangan ng malinis na kapaligiran ï¼
Mangyaring sundin ang aming manu-manong pag-installï¼


Pag-uuri


â¦Inuri ayon sa paggamit
â¦Inuri ayon sa antas ng proteksyon
(1)Walang plastic boxï¼ IP2L0
(2)May plastic boxï¼ IP65


Mga teknikal na parameter


Uri

 

FM30-25

FM30-32

FM30-40

FM30-63

FM30-100

FM30-125

Rated thermal current (Ith)

A

25

32

40

63

100

125

Rated working boltahe(Ue)

V

240 440

240 440

240 440

240 440

240 440

240 440

Halaga ng rating(le/kW)

             

AC-21A

A/kw

20/-20/-

32/-32/-

40/-40/-

63/-63-

100/-100/-

125/-125/-

AC-22A

A/kw

20/-20/-

32/-32/-

40/-40/-

63/-63-

100/-100/-

125/-125/-

AC-23A

VKW

15/4

15/7.5

22/5.5

22/11

30/7.5

30/7.5

43/11

43/22

70/22

70/22

 

AC-3

A/kw

11.7/3

11.7/5.5

15/4

15/7.5

22/7.5

22/11

36/11

36/18.5

57/18.5

57/30

 

Kasalukuyang uri: AC 50Hz
Bilang ng pangunahing contact: ON o OFF
Dalas: 8 oras na trabaho/paputol-putol na pana-panahong tungkulin, /h ang dalas ng operasyon ay 30 beses. Buhay ng kuryente: 10,000 beses / AC-23, 6,000 beses/ AC-3, mga pantulong na contact para sa 2000 beses.


Pag-uuri


FM30 Series door interlock Guide Installation D2(50/100/150/200)



Uri

Laki ng balangkas

laki ng pag-mount

A

LI

L

E

F

DI

D2

FM30-20

50

32

150

48

48

422

04.2
FM30-25

50

32

150

48

48

(D22

FM30-32

50

32

150

48

48

022

04.2
FM3040

61

32

150

48

48

022

0)4.2
FM30-63

61

32

150

48

48

(D4.2
FM30-80

68

32

150

48

48

(D22

(D4.2
FM30-100

68

32

150

48

48

022

04.2

Tandaan: Maaaring i-install ang produkto sa 35mm para sa I


Pinili ng AC Isolator - AC Electric Rotary Isolation Disconnect Switch


â¦Ang mga AC Isolator ay ginagamit sa parehong stand-alone na grid o network distributed system. Kung nakakonekta sa distributed network, ang G83/1 ay nagsasaad na ang PV system ay dapat na direktang konektado sa isang isolation switch na naka-wire upang ihiwalay ang parehong live at neutral na mga conductor, na may kakayahang ma-secure sa posisyon na âOFFâ at sa isang naa-access na lokasyon sa loob ng pag-install.
â¦Hindi tulad ng isang DC isolator na kinakailangan upang ilipat ang parehong positibo at negatibong konduktor, isang AC isolator ay dapat na mapili patungkol sa ang supply ay isang yugto, na karaniwang matatagpuan sa mga domestic installation o tatlong yugto, na karaniwan para sa komersyal o mga pang-industriyang instalasyon. Pinakamainam para sa isang yugto, isang 2pole isolator ang dapat gamitin upang ilipat ang live at neutral na linya (patuloy na konektado ang lupa) habang ang isang 4 na poste na isolator ay gagamitin upang ilipat ang 3 linya ng boltahe at neutral (patuloy na konektado ang lupa).
â¦Ang rating ng isolator ay dapat na nakabatay sa output ng inverter na karaniwang tinukoy sa bawat yugto, iyon ay line to neutral, at halimbawa ay maaaring ipakita bilang 20A sa 230VAC; kung ang output na ito ay mula sa isang three phase unit, ang AC isolator ay dapat na na-rate para sa line-to-line na boltahe na karaniwang magiging 415VAC.
â¦Sa parehong AC at DC isolator, dapat isaalang-alang ang ambient temperature ng kapaligiran kung saan naka-mount ang switch dahil karamihan sa mga pang-industriyang switch ay nominally na na-rate para gamitin sa 35°C. Gayunpaman, kung ang isolator ay gagamitin sa isang lugar kung saan ang solar activity ay laganap, sa gayo'y gumagawa ng mas mahusay na paggamit ng pag-install at mas mataas na ani, o sa isang nakapaloob na espasyo tulad ng isang loft o ng isang inverter enclosure, kung gayon ang isang isolator ay may kakayahang ng paghawak sa mataas na temperatura ay dapat piliin.



Mga Hot Tags: AC Electric Rotary Isolation Disconnect Switch, China, Mga Tagagawa, Supplier, Pabrika, Customized, Mga Brand, Listahan ng Presyo, Sipi, CE, Kalidad